Using "mender check-update" prevents the next scheduled periodic update check from happening.
Here is a log showing the problem:
You can see periodic checks happening every hour at 13 and 43 minutes (every 30 minutes) as configured.
At 13:45 I run a "mender check-update". Then at 14:13, nothing happens, and the cycle resumes at 14:43.
When running "mender check-update" several times, this effect amplifies. For example if you run it 5 times, nothing will happen for the next 2:30 and then updates will resume.
Expected behavior: scheduled updates should continue to happen, or possibly, the next update should be 30 minutes after the manual "mender check-update" run.
Using "mender check-update" prevents the next scheduled periodic update check from happening.
Here is a log showing the problem:
You can see periodic checks happening every hour at 13 and 43 minutes (every 30 minutes) as configured.
At 13:45 I run a "mender check-update". Then at 14:13, nothing happens, and the cycle resumes at 14:43.
When running "mender check-update" several times, this effect amplifies. For example if you run it 5 times, nothing will happen for the next 2:30 and then updates will resume.
Expected behavior: scheduled updates should continue to happen, or possibly, the next update should be 30 minutes after the manual "mender check-update" run.